Practical example
The configured 480 V DC drive system consists of:
Number | Component |
|---|---|
4 | Servomotors from the AM8031-0D21 series with cable lengths of 4 m, 10 m, 15 m and 22 m |
4 | Servomotors from the AM8051-0G21 series with cable lengths of 16 m, 18 m, 21 m and 25 m |
4 | Dual-axis modules from the AX8206 series |
1 | Power supply modules from the AX8620 series |
Total standstill current I0
The total standstill current I0 relates to all servomotors listed in the practical example and corresponds to:
- 4 x 1.95 A for the AM8031 + 4 x 4.75 A for the AM8051 = 26.8 A
The total standstill current I0 is now multiplied by the simultaneity factor. In the case of a machine tool this is relatively high, e.g. 0.9, because all axes can drive into the material at the same time. In the case of a handling system the factor is more likely to be 0.7. This then corresponds to:
- 26.8 A x 0.7 = 18.76 A
The AX8620 power supply module was selected on the basis of the calculations.
24 VDC current consumption
The 24 V DC current consumption relates to all the components listed in the practical example and corresponds to:
- 0.12 A for the AX8620 + 4 x 0.57 A for the AX8206 + 4 x 0.33 A for the holding brake with the AM8031 + 4 x 0.54 A for the holding brake with the AM8051 = 5.88 A DC
Result
The maximum single cable length for the AM8051-0G21 is 25 m and is thus ≤ 25 m
The total cable length of all servomotors is 131 m and is thus ≤ 300 m
- No AX2090-ND80-xxxx mains choke required
The 24 V DC current consumption of all components is 5.88 A DC and is therefore ≤ 20 A DC
- 24 V DC power supply unit with at least 6 A rated current provided
The maximum DC link capacitance is always related to the connection to a common AX8620 power supply module with 945 µF and is thus ≤ 6000 µF