AX81xx-0x10 with 2 x D-sub

AX81xx-0x10 with 2 x D-sub 1:

Two D-sub connectors (X11/X12) are available for the AX81xx-0x10 single-axis module:

Typical applications

Supported digital feedback protocols:

Pin assignment X11/X12

Pin

EnDat® 2.2/22

BiSS® C

1

n.c.

n.c.

2

GND

GND

3

n.c.

n.c.

4

5 V DC ±10%

5 V DC ±10%

5

Data; DX+ Data

Data+ / SLO+

6

Us 11 V DC 1)

Us 11 V DC 1)

7

n.c.

n.c.

8

Clock; CLK+

CLK+ / MA+

9

n.c.

n.c.

10

GND sense

GND sense

11

n.c.

n.c.

12

5 V sense

5 V sense

13

Data; DX-

Data- / SLO-

14

n.c.

n.c.

15

Clock; CLK-

CLK- / MA-

1) When using encoders with 11 V DC supply voltage (pin 6), the sense pins (10 and 12) must not be assigned.

Only one protocol can be set per module.

Maximum output current per D-sub connector: 250 mA