Beckhoff linear servomotors

The axis modules of the AX8000 servo system also support safe drive technology with AL8000 linear servomotors. A suitable external encoder system must be selected. Please observe the following notes.

Notice

TwinSAFE STO/SS1

The basic TwinSAFE STO/SS1 functions can be used with linear motors. The connected feedback is not relevant here.

Notice

TwinSAFE Safe Motion

The sophisticated TwinSAFE Safe Motion safety functions require the connection of a functional safety encoder (Safe Motion Encoder):

  • Hiperface DSL (Functional Safety)
  • EnDat® 2.2/22 (Functional Safety)
  • EnDat® 3 (Functional Safety)

Notice

Non-observance may endanger product safety

If an external encoder is used, the machine builder is responsible for

  • the right choice of components
  • correct installation in accordance with the encoder operating instructions
  • assembling and testing the required encoder connection cable in accordance with the encoder operating instructions
  • the FMEDA (Failure modes, effects and diagnostic analysis)