Integration into TwinCAT
| The brake module can be integrated in the TwinCAT System Manager as a completely normal I/O device (1) and is parameterized (3) with the TCDrive Manager (2). |
Configuration in the TC Drive Manager
Power Management

Pos. | Name |
| Pos. | Name |
|---|---|---|---|---|
1 | Power management |
| 6 | Activation / deactivation of the internal brake resistor |
2 | Mains voltage selection |
| 7 | External brake resistor parameter list |
3 | Phase monitoring (deactivate for single-phase mains) |
| 8 | 0 = Deactivation of the external brake resistor |
4 | Delay time until the phase monitoring responds (activate if mains is unclean) |
| 9 | Enabling / disabling the fan of the external brake resistor and setting the switching thresholds Switch on Level: Percentage specification of the rated capacity value of the external brake resistor.Switch on Temp.: Max. temperature value for the external brake resistor in "°C". |
5 | Internal brake resistor parameter list |
|
|
|