Feedback cables for Beckhoff motors
Notice  | |
EMC-Safety! At all cables, do not connect the wires marked with "n.c.".  | 

Encoder cable for AL2000 / AM3000 / AM3500 with EnDat-, BiSS or Hiperface interface and sine / cosine without zero pulse
Article number  | Number of conductors and wire cross-section  | Installation  | 
|---|---|---|
ZK4510-0000-xxxx  | 7x(2x0.14) + 2x0.5 mm²  | fixed installation  | 
ZK4510-0020-xxxx  | 7x(2x0.14) + 2x0.5 mm²  | highly dynamic  | 
Circular plug 17-pole  | Contact  | Function  | Core identification  | Contact  | D-sub 15-pole  | |
|---|---|---|---|---|---|---|
  | Rev. 02  | |||||
 View X  | 1  | REFSIN  | white  | red / blue  | 9  |     View Y  | 
2  | GND_5 V / 9 V  | red/blue  | white 0,5 mm2  | 2  | ||
3  | REFCOS  | green  | green  | 11  | ||
4  | Us_5 V  | grey / pink  | brown 0,5 mm2  | 4  | ||
5  | DX+ Data  | grey  | grey  | 5  | ||
6  | Us_9 V  | brown / green  | brown / green  | 6  | ||
7  | n.c.  | 
  | 
  | n.c.  | ||
8  | CLK+ Clock  | blue  | blue  | 8  | ||
9  | SIN  | brown  | grey / pink  | 1  | ||
10  | GND_Sense  | violet  | violet  | 10  | ||
11  | COS  | yellow  | yellow  | 3  | ||
12  | Us_5 V_Sense  | black  | black  | 12  | ||
13  | DX- Data  | pink  | pink  | 13  | ||
14  | n.c.  | 
  | 
  | n.c.  | ||
15  | CLK- Clock  | red  | red  | 15  | ||
16  | n.c.  | 
  | 
  | n.c.  | ||
17  | n.c.  | 
  | 
  | n.c.  | ||
Encoder cable for AL2000 with sine / cosine encoder with zero pulse
Article number  | Number of conductors and wire cross-section  | Installation  | 
|---|---|---|
ZK4520-0020-xxxx  | 7x(2x0.14) + 2x0.5 mm²  | highly dynamic  | 
  | 
  | Function  | 
  | 
  | 
  | |
|---|---|---|---|---|---|---|
Circular plug 17-pole  | Contact  | SIN / COS  | TTL  | Core identification  | Contact  | D-sub 15-pole  | 
 View X  | 1  | REFSIN  | ---  | red / blue  | 9  |     View Y  | 
2  | GND_5 V / 9 V  | GND_5 V / 9 V  | white 0,5 mm2  | 2  | ||
3  | REFCOS  | ---  | green  | 11  | ||
4  | Us_5 V  | Us_5 V  | brown 0,5 mm2  | 4  | ||
5  | ---  | B +  | grey  | 5  | ||
6  | Us_9 V  | Us_9 V  | brown / green  | 6  | ||
7  | REF Z  | REF Z  | white / yellow  | 7  | ||
8  | ---  | A +  | blue  | 8  | ||
9  | SIN +  | ---  | grey / pink  | 1  | ||
10  | GND_Sense  | GND_Sense  | violet  | 10  | ||
11  | COS +  | ---  | yellow  | 3  | ||
12  | Us_5 V_Sense  | Us_5 V_Sense  | black  | 12  | ||
13  | ---  | B -  | pink  | 13  | ||
14  | Z +  | Z +  | brown / yellow  | 14  | ||
15  | ---  | A -  | red  | 15  | ||
16  | n.c.  | n.c.  | 
  | ---  | ||
17  | n.c.  | n.c.  | 
  | ---  | ||
Resolver cable for AM2000 / AM3000 / AM3500
Article number  | Number of conductors and wire cross-section  | Installation  | 
|---|---|---|
ZK4530-0010-xxxx  | 4x2x0,25 mm²  | dynamic  | 
Circular plug 12-pole  | Contact  | Function  | Core identification  | Contact  | D-sub 15-pole  | 
|---|---|---|---|---|---|
 View X  | 1  | n.c.  | 
  | n.c.  | 
 View Y  | 
2  | Temerature (only PTC, Klixon or Bimetal!)  | blue  | 1  | ||
3  | COS - (S3)  | yellow  | 3  | ||
4  | SIN - (S4)  | brown  | 4  | ||
5  | REF - (R2)  | pink  | 5  | ||
6  | GND_Temp.  | red  | 9  | ||
7  | COS + (S1)  | green  | 10  | ||
8  | SIN + (S2)  | white  | 11  | ||
9  | REF + (R1)  | grey  | 12  | ||
10  | n.c.  | 
  | n.c.  | ||
11  | n.c.  | 
  | n.c.  | ||
12  | n.c.  | 
  | n.c.  | 
 