Commutation error during regular operation (very rare)

Under special operating conditions the regular operation of the axes can fulfil the three conditions mentioned above and therefore trigger this error message despite correct commutation. A number of examples are given below which, however, occur very seldom:

  1. When the servo drive is operating at its limit (conditions 1 and 3 are met) and external forces cause a counteracting torque which then fulfils condition 2, the servo drive generates a commutation error.
  2. The servo drive is operating at its limit (conditions 1 and 3 are met) and rapid changes in direction or speed result in an oscillating current curve. Condition 2 is then also met and a commutation error arises.

If these examples do not apply to your application, analyze the application and try to find the cause. If you are unable to remedy the cause but still wish to operate the axis, there is only one option for suppressing the commutation error:

Parameterize the value of the IDN P-0-0069 to the permitted maximum speed of the motor so that point 1 of the above-mentioned factors cannot apply and the commutation error will no longer appear.

WARNING

Warning, risk of injury from uncontrolled movements!

Increasing the value of the IDN "P-0-0069" to the highest speed always means that the commutation monitoring will no longer cause errors, even if other circumstances actually require this. This is particularly critical when the motor is being replaced. If the value of the IDN "P-0-0069" is NOT reset, then uncontrolled movements of the motor may occur. Beckhoff recommends that you should NOT increase the value of the IDN "P-0-0069".

Commutation error during regular operation (very rare) 1:

Drive design

The drive should generally not be designed to operate at its limit, i.e., the current should not exceed 90% of the value specified in P-0-0092 "Configured channel peak current".