Error reset (command S-0-0099)
It is possible to acknowledge a pending error using the navigation rocker and the display. The error acknowledgement via the display is identical to calling the SoE reset command S-0-0099.
Overview

Executing the command
Press the right-hand side of the rocker
three times until the following display appears: 
Display on the AX5000 | Description |
|---|---|
| 1 = “M” indicates that the “menu mode” is activated. |
There are now 2 possibilities:
Press the center of the rocker
for approx. 3 sec. to execute the reset command for channel “A” or
press the upper or lower side of the rocker
and switch to channel “B”. Now press the center of the rocker
for approx. 3 seconds and execute the reset command for channel “B.” The following display appears
.
Once the error has been corrected, the standard display will appear. If the error display is still active afterwards, you have not been able to rectify the cause of the error or further errors are pending.