General

Starting from the standard display, you can access the configuration and command displays by pressing the right side of the navigation rocker General 1:. If you are in another menu item and do not change the display for approx. 25 seconds, or if there are no active diagnostic messages, the standard display is automatically shown again.

General 2:

Display on the AX5000

Description

General 3:

The display consists of 2 lines. These two lines display independent, configurable contents.
The contents can be arranged into 4 groups.

General 4:

Cyclic values (standard display):
The so-called standard display is shown permanently. Various parameterizable values can be displayed in the two lines. The two lines are preconfigured in the factory as follows:

Line 1: Current EtherCAT status
Line 2: Current DC link voltage

General 5:

Error messages:
If an error occurs, the display alternates between the diagnostic code (hex) and a brief description of the error message (2+3). If the error concerns only channel "A", then this display is shown only in the upper line; the standard text remains in the lower line. If the error concerns only channel "B", then this display is shown only in the lower line; the standard text remains in the upper line. In both cases, the display light (2-5) also flashes.

If the error has been corrected and acknowledged with the reset command (S-0-0099), the standard display with the cyclic values appears again (see above).

see error messages

Warnings:
If a warning occurs, the display behaves in the same way as with an error message.

see error messages

Information:
If an information message occurs, the display behaves in the same way as with an error message, but does not flash.