Electrical data – servo drive (AX52xx)

1-phase connection

Electrical data

AX5201

AX5203

AX5206

Rated output current / channel

1.5 A

3 A

4.5 A

Smallest parameterizable channel peak current at full current resolution

0.35 A

1 A

1 A

Largest parameterizable channel rated current

3 A

4.5 A

9 A

Rated sum current

3 A

4.5 A

9 A

Max. peak output current 1) / channel

5 A

10 A

13 A

Peak output current 1) as total device current

10 A

20 A

26 A

Rated supply voltage

1 x 100-10% – 240+10% V AC

Max. DC link voltage

875 V DC

Rated apparent power S1 operation (selection)
120 V
230 V


0.6 kVA
1.2 kVA


1.2 kVA
2.4 kVA


2.5 kVA
4.8 kVA

Power loss 2)

55 W

85 W

160 W

Max. continuous braking power (internal braking resistor)

50 W

150 W

90 W

Max. braking power (internal braking resistor)

14 kW

Min. braking resistor (external braking resistor)

47 Ω

Max. braking power (external braking resistor)

15 kW

DC link capacitance

235 µF

470 µF

SCCR value

18 kA

1) Irms for max. 7 s, at a clock frequency of 8 kHz (IDN P-0-0001)
2)
S1 Operation incl. power supply unit, without brake chopper

3-phase connection

Electrical data

AX5201

AX5203

AX5206

Rated output current / channel

1.5 A

3 A

6 A

Smallest parameterizable channel peak current at full current resolution

0.35 A

1 A

1 A

Largest parameterizable channel rated current

3 A

6 A

9 A

Rated sum current

3 A

6 A

12 A

Max. peak output current (1) / channel

5 A

10 A

13 A

Peak output current (1) as total device current

10 A

20 A

26 A

Rated supply voltage

3 x 100-10% – 480+10% V AC

Max. DC link voltage

875 V DC

Rated apparent power S1 operation (selection)
120 V
230 V
400 V
480 V


0.6 kVA
1.2 kVA
2.1 kVA
2.5 kVA


1.2 kVA
2.4 kVA
4.2 kVA
5.0 kVA


2.5 kVA
4.8 kVA
8.3 kVA
10.0 kVA

Power loss (2)

55 W

85 W

160 W

Max. continuous braking power (internal braking resistor)

50 W

150 W

90 W

Max. braking power (internal braking resistor)

14 kW

Min. braking resistor (external braking resistor)

47 Ω

Max. braking power (external braking resistor)

15 kW

DC link capacitance

235 µF

470 µF

SCCR value

18 kA

1) Irms for max. 7 s, at a clock frequency of 8 kHz (IDN P-0-0001)
2)
S1 Operation incl. power supply unit, without brake chopper