Electrical data – servo drive (AX5101...AX5140)
1-phase connection
Technical data | AX5101 | AX5103 | AX5106 |
|---|---|---|---|
Rated output current | 1.5 A | 3 A | 4.5 A |
Smallest parameterizable channel peak current at full current resolution | 0.35 A | 1 A | 1 A |
Peak output current 1) | 4.5 A | 7.5 A | 13 A |
Rated supply voltage | 1 x 100-10%…240+10% V AC | ||
Max. DC link voltage 2) | 875 V DC | ||
Rated apparent power S1 operation (selection) |
|
|
|
Power loss 3) | 35 W | 50 W | 85 W |
Continuous braking power (internal braking resistor) | 50 W | 50 W | 150 W |
Max. braking power (internal braking resistor) | 14 kW | ||
Min. braking resistor (external braking resistor) | 47 Ω | ||
Max. braking power (external braking resistor) | 15 kW | ||
DC link capacitance | 235 µF | ||
SCCR value | 18 kA | ||
1) Irms for max. 7 s, at a clock frequency of 8 kHz (IDN P-0-0001)
2) Info: The higher the power consumption in the DC link, the more the DC link voltage drops
3) S1 Operation incl. power supply, without brake chopper
3-phase connection
Electrical data | AX5101 | AX5103 | AX5106 | AX5112 | AX5118 | AX5125 | AX5140 | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Rated output current | 1.5 A | 3 A | 6 A | 12 A | 18 A | 25 A1) | 40 A | ||||
Smallest parameterizable channel peak current at full current resolution | 0.35 A | 1 A | 1 A | 6 A | 12 A | 12 A | 18 A | ||||
Peak output current 3) | 4.5 A | 7.5 A | 13 A | 26 A 4) | 36 A | 50 A | 80 A | ||||
Rated supply voltage | 3 x 100-10%…480+10% V AC2) | ||||||||||
Max. DC link voltage | 875 V DC | ||||||||||
Rated apparent power S1 operation (selection) |
|
|
|
|
|
|
| ||||
Power loss 5) | 35 W | 50 W | 85 W | 160 W | 255 W | 340 W | 510 W | ||||
Max. continuous braking power (internal braking resistor) | 50 W | 50 W | 150 W | 90 W | 200 W | 200 W | 150 W | ||||
Braking power (internal braking resistor) | 14 kW | 26 kW | 26 kW | 26 kW | |||||||
Min. braking resistor (external braking resistor) | 47 Ω | 47 Ω | 47 Ω | 30 Ω | 22 Ω | 22 Ω | 22 Ω 6) | ||||
Max. braking power (external braking resistor) | 15 kW | 15 kW | 15 kW | 23.5 kW | 32 kW | 32 kW | 32 kW | ||||
DC link capacitance | 235 µF | 470 µF | 940 µF | 1175 µF | 1485 µF | ||||||
SCCR value | 18 kA | ||||||||||
1)cULus = 24 A
2)cULus = AX5118 and AX5125 = 3 x 480 VAC ± 10%
3) Irms for max. 7 s, if clock frequency 8 kHz (IDN P-0-0001)
4) Irms for max. 7 s, if rotating field frequency ≥ 1.5 Hz
Irms for max. 1 s, if rotating field frequency < 1.5 Hz
5) S1 operation incl. power supply unit, without brake chopper
6) Braking resistor < 22 Ω – > Please ask our support