No. | Description |
|---|---|
F870 | „Encoder not ready“ – execute the RESET command (S-0-0099) |
F872 | „Error flag active“ – status changes to „Safe-Op“. Restart required. |
F873 | „Get position timeout“ – status changes to „Safe-Op“. Restart required. |
F874 | “Crc memory error”– execute the RESET command (S-0-0099) |
F875 | “No EnDat 2.2 encoder connected”– execute the RESET command (S-0-0099) |
F876 | “UART Error”– execute the RESET command (S-0-0099) |
F877 | “Out of memory”– execute the RESET command (S-0-0099) |
F879 | “Callibration error”– execute the RESET command (S-0-0099) |
F87A | “AX572x power supply error”– execute the RESET command (S-0-0099) |
F87C | “AX572x protocol not supported”– execute the RESET command (S-0-0099) |
F87D | “AX572x wrong parameter”– execute the RESET command (S-0-0099) |