Safety regulations
The responsible staff must ensure that the application or use of the products described satisfy all the security requirements, including all the relevant laws, regulations and guidelines.
| |
Serious risk of injury through electric shock! Due to the DC link capacitors, the DC link contacts "DC+ and DC-" and "RB+ and RB-" may be subject to dangerous voltages exceeding 875 VDC, even after the servo drive was disconnected from the supply network. Wait 5 minutes for the AX5101 - AX5125 and AX520x; 15 minutes for the AX5140/AX5160/AX5172; 30 minutes for the AX5190/AX5191; 45 minutes for the AX5192/AX5193 after disconnecting, and measure the voltage at the DC links again. The device is safe once the voltage has fallen below 50 V. |
| |
Caution - Risk of injury! Basically, electronic devices are not fail-safe. The machine builder is responsible for ensuring that the connected motors and the machine are brought into a safe state in the event of a fault in the drive system. |
Notice | |
Caution Destruction of the digital encoder option cards! The encoder option card is an ESD-sensitive component. Be sure to observe the ESD protection measures when handling the card. |
NOTICE | ||
![]() | UL approval! If you intend to operate an AX5000 in a region that requires UL approval, please refer to the chapter "Guidelines and Standards". | |

