Safety regulations
The responsible staff must ensure that the application or use of the products described satisfy all the safety requirements, including all the relevant laws, regulations and guidelines.
| |
Caution - Danger of death! Even if the AX5000 is disconnected from the mains voltage, life-threatening voltage is still present at the “X02” terminals of the DC link for 5 minutes. Before touching live terminals, wait for the DC link capacitors to discharge. The voltage measured between the DC+ and DC- terminals (X02) must have dropped to below 50 V. |
| |
Caution – Risk of injury! Basically, electronic devices are not fail-safe. The machine builder is responsible for ensuring that the connected motors and the machine are brought into a safe state in the event of a fault in the drive system. |
Notice | |
Caution – Destruction of the encoder option card through electrostatic charging! The encoder option card is an ESD-sensitive component. Follow the usual ESD safety procedures when handling the card (anti-static wrist straps, grounding of the relevant components etc.). |
NOTICE | ||
![]() | UL approval! If you intend to operate an AX5000 in a region that requires UL approval, please refer to the chapter “Guidelines and Standards”. | |