Cables

Beckhoff Automation GmbH & Co. KG offers pre-assembled cables for safe, faster and flawless installation of the motors. Beckhoff cables have been tested with regard to the materials, shielding and connection technology used. They ensure proper functioning and compliance with statutory regulations such as EMC, UL etc. The use of other cables may lead to unexpected interference and invalidate the warranty.

WARNING

Caution - Fire hazard!

The braking resistors can reach temperatures of almost 200°C. Therefore, ensure adequate thermostability of the cables! Cables with inadequate thermostability can cause a cable fire!

Notice

EMC safety

Use only shielded cables

 

Type

Braking resistor

Temperature switch

[mm2]

[AWG]

[mm2]

[AWG]

AX2090-BW50-0300

1.5

16

0.75

18

AX2090-BW50-0600

1.5

16

0.75

18

AX2090-BW50-1600

1.5

16

0.75

18

AX2090-BW51-1000

2.5

12

0.75

18

AX2090-BW51-3000

2.5

12

0.75

18

AX2090-BW51-6000

2.5

12

0.75

18

AX2090-BW52-3000

4.0

12

0.75

18

AX2090-BW52-6000

4.0

12

0.75

18

AX2090-BW53-3000

6.0

12

0.75

18

AX2090-BW53-6000

6.0

12

0.75

18

AX2090-BW54-3000

6.0

12

0.75

18

AX2090-BW54-6000

6.0

12

0.75

18

We recommend ferrules.