Intended use

The external braking resistors of the AX2090-BW5x-xxxx series are able to convert the dynamic energy generated during braking of a servomotor into heat. The series covers a wide continuous power and peak power range. The built-in temperature switch enables the system to respond immediately to any overload of the braking resistor through analysis in the AX5000 or the PLC. All braking resistors of the AX2090-BW5x-xxxx series are UL and CSA approved.

WARNING

Risk of injury from electronic devices that are not fail-safe!

Electronic devices are fundamentally not fail-safe. In the event of a drive system failure, the machine builder is responsible for ensuring that the connected motors and the machine or system are brought to a safe and voltage-free state.

The braking resistors from the AX2090-BW5x-xxxx series are exclusively designed for direct application with an AX5000 series servo drive or the AX5021 brake module. Together with the servo drive or brake module, they are installed as components in electrical systems and machines and may only be operated there. Furthermore, the ambient and operating conditions described in the chapter "Technical data" must be observed.

Improper use

The external braking resistors from the AX2090-BW5x-xxxx series are not suitable for use in the following areas:

The relevant standards and directives for EMC interference emissions must be complied with in residential areas. The servo drives may only be installed in housings and control cabinets with appropriate shielding attenuation.