Fuse protection
External protection for individual devices, CE-compliant
| |
Fire hazard through short circuit! The recommended fuses are used for line protection. The servo drives are equipped with integrated self-protection. |
|
Fuse protection |
AX5160 |
AX5172 |
AX5190 |
AX5191 |
AX5192 |
AX5193 |
|---|---|---|---|---|---|---|
|
AC supply (max.)* |
80 A |
100 A |
125 A |
160 A |
200 A |
224 A |
|
24 V supply (max.) |
4 AT |
10 AT | ||||
|
Braking resistor |
electronic | |||||
*) Application class "gG" mains fuses according to IEC60269 or "C" type automatic circuit breakers must be used.
External protection for individual devices, UL-compliant
| |
Fire hazard through short circuit! The recommended fuses are used for line protection. The servo drives are equipped with integrated self-protection. |
|
Fuse protection |
AX5160 |
AX5172 |
AX5190 |
AX5191 |
AX5192 |
AX5193 |
|---|---|---|---|---|---|---|
|
AC supply (max.)* |
|
|
|
|
|
|
|
24 V supply (max.) |
4 AT |
10 AT | ||||
|
Braking resistor |
electronic | |||||
*) Application class "gG" mains fuses according to IEC60269 or "C" type automatic circuit breakers must be used.