External protection for individual devices, CE-compliant

CAUTION

Fire hazard due to overload of the connection cable!

  • The following data refer to stand-alone devices. Please note the sum current of all connected devices in a multi-axis system.
  • The recommended fuses are designed for line protection. The servo drives feature integrated self-protection.

Single-phase

 

AX5101

AX5103

AX5106

AX5201

AX5203

AX5206

AC supply*)

10 A

10 A

16 A

10 A

16 A

20 A

24 V DC supply

5 AT

Braking resistor

electronic

*) Mains fuses of class “gG” or circuit breakers with characteristic “C” must be used.

Three-phase

 

AX5101

AX5103

AX5106

AX5201

AX5203

AX5206

AC supply *)

6 A

6 A

10 A

10 A

10 A

20 A

24 V DC supply

5 AT

Braking resistor

electronic

 

AX5112

AX5118

AX5125

AX5140

AC supply *)

20 A

35 A

35 A

50 A

24 V DC supply

5 AT

Braking resistor

electronic

*) Mains fuses of class “gG” or circuit breakers with characteristic “C” must be used.

Internal protection, CE-compliant

Circuit

Fuse

24 V DC system voltage

3.4 AF

24 V DC peripheral voltage

electronic

Braking resistor

electronic