Image showing AX5190 - AX5191
The servo drive shown below is a AX5190; the AX5191 is identical.
|
Item descriptions:
No. | Name | No. | Name |
|---|---|---|---|
1 | X4x - optional slot for expansion cards | 9 | X14 - sensor for motor temperature and brake |
2 | X3x - optional slot for safety card | 10 | DC link output (875 V DC voltage), connection for the external brake resistor |
3 | X12 - feedback connection, encoder | 11 | Motor connection (U, V, W, PE) |
4 | X06 - connection for digital inputs and outputs | 12 | X04 - socket for EtherCAT input |
5 | Navigation rocker | 13 | Labelling field |
6 | Labelling field | 14 | Display |
7 | X05 - socket for EtherCAT output | 15 | X11 - feedback connection, resolver |
8 | X03 - power supply 24 V DC input | 16 | X01 - mains supply |
| |
Serious risk of injury through high electrical voltage! Due to the DC link capacitors, the DC link terminal points "DC+ and DC-" and "RB+ and RB-" may be subject to dangerous voltages exceeding 875 VDC, even after the servo drive was disconnected from the mains supply. |