Checking the scaling factor
In the Solution Explorer, open Motion → NC-Task 1 SAF → Axes → Axis 1 → Enc (1)
Open the Parameter tab (2)
Compare the value of the Scaling Factor Numerator (3) with the value of the scaling factor
If the value does not match the scaling factor, select the field (3) and enter the scaling factor. CAUTION: Please ensure decimal points are used, not decimal commas, as used in Germany!

The value change is indicated by the blue color of the (4) field.
Select the field with the changed value (4) to activate the Download button (5)
Press Download (5) to save the change
Another prompt appears:

Save changes permanently with Save now
Wait a moment and close the window with OK
Also check the settings of Channel B.

Setting the velocities
In the Solution Explorer, open Motion → NC-Task 1 SAF → Axes → Axis 1 (6)
Open the Parameter tab (7)
Set the velocities as required
CAUTION: Please ensure decimal points are used, not decimal commas, as used in Germany!

The value change is indicated by the blue color of the field.
Parameter | Description |
|---|---|
Reference Velocity | Reference velocity of an analog servo drive |
Maximum Velocity | Maximum velocity (= maximum value of the Target Velocity field) |
Manual Velocity (Fast) | Velocity in the manual test menu (F1 and F4) |
Manual Velocity (Slow) | Velocity in the manual test menu (F2 and F3) |
Calibration Velocity (towards plc cam) | Homing velocity |
Calibration Velocity (off plc cam) | Homing velocity |
→ The velocities are adjusted and take effect with the next configuration.