Creating an NC axis
If an NC axis configuration has already been created, the individual axes can be created and linked.
The Motion section of the Solution Explorer expands and shows the new NC axis configuration.


Right-click on Axes within the axis configuration
Select Add New Item…
Enter a name for the NC axis (1)
Determine the axis type (2)
Confirm entries with OK

In the Solution Explorer the new axis appears with its name within the NC axis configuration. Link the individual NC axes with the drive, in order to enable control.
Open Axis 1 in the Solution Explorer
Switch to the Settings tab
Link the NC axis with the hardware axis via Link To I/O… (3)

Select the drive to be linked from the list
You can filter the list based on the axis link status. The Unused (4) filter only shows axes that are not linked. The All (4) setting shows all axes, irrespective of their link status.
Confirm the selection with OK
→ Your NC axis is successfully linked with the drive.