Max. cable lengths including extensions

Rated motor voltage up to 400 V AC

Motor choke

AX5101…AX5112, AX52xx

AX5118, AX5125

AX5140

C2 1)

C3

C2 1)

C3

C2

C3

Without

<25 m

<25 m

<25 m

<25 m

-

<30 m

AX2090-
MD50-0012

<100 m

<100 m

-

-

-

-

AX2090-
MD50-0025

-

-

<50 m

<50 m

-

-

1) For compliance with EN 61800-3 only with mains filter AX2090-NF50-0014.
2) For compliance with EN 61800-3 only with mains filter AX2090-NF50-0032.

Max. cable lengths including extensions 1:

Sensitive sensors

In exceptional cases (sensitive sensors, etc.) it can be necessary to use a motor choke even for motor cable lengths <25 m.

Rated motor voltage up to 480 V AC

Motor choke

AX5101…AX5112, AX52xx

AX5118, AX5125

AX5140

C2 1)

C3

C2 2)

C3

C2

C3 3)

Without

<20 m

<20 m

<20 m

<20 m

-

4)

AX2090-
MD50-0012

<100 m

<100 m

-

-

-

-

AX2090-
MD50-0025

-

-

<50 m

<50 m

-

-

1) For compliance with EN 61800-3 only with mains filter AX2090-NF50-0014.
2) For compliance with EN 61800-3 only with mains filter AX2090-NF50-0032.
3) C3 with up to 70 m without mains choke possible for devices with order number AX5140-0000-1202.
4) Please contact our applications department

In exceptional cases (sensitive sensors, etc.) it can be necessary to use a motor choke even for motor cable lengths <20 m.

To keep line perturbations (distortion reactive power) as low as possible, a mains choke should always be used.

Max. cable lengths including extensions 2:

Malfunction in residential areas

Mains chokes are products with restricted availability in accordance with EN 61800-3. The products may cause radio interference in residential areas. In this case, necessary measures must be taken by the operator.