Electrical installation
| UL approval! If you want to operate an AX5000 in the USA or Canada, be sure to observe chapter 3.3. |
| Drive system with UL approval Please consult our applications department with respect to the requirements for a drive system with UL approval. |
| |
Serious risk of injury from electric shock Due to the DC link capacitors dangerous voltage may persist at the DC link contacts "X02" after the servo drive has been disconnected from the supply network. Wait 5 minutes after disconnecting and measure the voltage at the DC link contacts DC+ and DC-. The device is safe once the voltage has fallen below 50 V. |
| |
Serious risk of injury from electric shock Before installation, wiring and commissioning it is essential to read the chapter "Safety". Before installing, uninstalling or wiring the servo drives and the motors please note the following:
|
| |
Destruction of the devices Check the rated voltage and current of the servo drive and the connected motors. Once the AX5000 has been disconnected from the supply network, (emergency shutdown, mains contactor etc.), wait at least 3 minutes before switching it on again or query the status of IDN "P-0-0205" (see "IDN description" in the documentation). |