Permissible ambient and operating conditions
Ambient / operating conditions | Permissible values |
|---|---|
Ambient temperature during operation | 0 °C...+50 °C |
Ambient temperature for transport/storage | -25 °C...+70 °C |
Air humidity | 5% to 95%, non-condensing |
Pollution degree | 2 according to EN 60204 / EN 50178 |
Corrosion protection | Normally not required. Under extreme operating conditions separate measures must be agreed with the manufacturer. |
Operating altitude | up to 1000 m above sea level without power derating from 1000 m up to 3000 m with power derating 1.5% / 100 m. |
Installation position | vertical |
Ventilation | Total device current ≤ 3 A: free convection Total device current > 3 A: built-in temperature-controlled fan |
Protection rating | IP20 |
Vibration test (EN 60068-2-6) | Frequency range: 10…500 Hz |
Shock test (EN 60068-2-27) | Half sine wave amplitude: 5 g Duration: 30 ms Number of impacts: 3 per axis and direction (18 impacts total) |
Repetitive shock test (EN 60068-2-27) | Half sine wave amplitude: 5 g Duration: 30 ms Number of impacts: 1000 per axis and direction (6000 impacts total) |