S-0-0031 Hardware version
The parameter contains information about the current hardware. It describes the PCB of the AX5000 with the associated hardware and firmware version.
Attributes
Name | Value |
---|---|
Datatype | text |
Data length in bit | 400 |
Decimal point | 0 |
Min value | - |
Default | 0 |
Max value | - |
Unit | - |
Changeable in EtherCAT state | No |
Cyclic transfer | No |
Device parameter | Yes |
Related to interface revision | No |
The information consists of letters and characters. The letters stand for PCBs. In addition, four characters are created. The first two characters indicate the hardware index, the following two characters indicate the firmware index of the PCB. Beckhoff support could query this information.

1: Safety board
2: Option board
3: Front board
4: Driver board
5: Power board
6: Control board
Example: c: 00001
Control board, hardware index 00, firmware index 01
![]() | Nested structure Note the nesting depth and the structure information at the start of the descriptions. |