S-0-0112 Amplifier rated current
The amplifier rated current is a hardware related limit, which means that continuous torque / force is limited. In case of a two channel device this parameter is limiting the sum of the configured channel rated currents (P-0-0093).
![]() | For further information please look into the involved IDN: |
Due to the configured supply voltage, amplifier peak voltage (S-0-0110), channel peak current (P-0-0090), amplifier rated current (S-0-0112) and channel rated current (P-0-0091) may change.
Further Information
- AX5101 Amplifier rated current
- AX5103 Amplifier rated current
- AX5106 Amplifier rated current
- AX5112 Amplifier rated current
- AX5118 Amplifier rated current
- AX5125 Amplifier rated current
- AX5140 Amplifier rated current
- AX5160 Amplifier rated current
- AX5172 Amplifier rated current
- AX5190 Amplifier rated current
- AX5191 Amplifier rated current
- AX5192 Amplifier rated current
- AX5193 Amplifier rated current
- AX5201 Amplifier rated current
- AX5203 Amplifier rated current
- AX5206 Amplifier rated current