Parameter description
IDN S-0-0216 (Switch parameter set)
Command for executing the parameter set switchover
IDN S-0-0217 (Parameter set preselection)
The parameter number for the switchover is entered in this IDN. If, for example, 2 is entered here and then the command S-0-0216 is executed, the parameter of parameter set S/P-2-xxxx are activated.
IDN S-0-0219 (IDN-list of parameter set)
This table contains all IDNs for which parameter sets 0 to 7 are available.
IDN S-0-0254 (Actual parameter set)
This IDN indicates the currently active parameter set.
IDN P-0-0360 (Parameter set prearrangement)
This IDN is used to specify how many parameter sets are prepared for switchover in the AX5000. If this IDN is parameterized to 3 it is possible to switch between parameter sets 0 to 3.
IDN P-0-0361 (Parameter set configuration)
This list is intended for the IDNs to be switched, which should also be listed in S-0-0219. The parameters of the IDNs entered here are prepared for parameter set switchover and switched accordingly.