FA82, Feedback "Resolver": Initialization of the sampling instance failed
Initialization of the sampling time points has failed.
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
---|---|
FA82 |
64130 |
Class |
Type |
---|---|
Error |
Runtime error |
Standard Reaction |
Reset |
---|---|
Open loop ramp |
Execute Reset-Command (S-0-0099). |
Possible Causes |
Solutions |
---|---|
The resolver cabling is faulty. |
Please check the cabling. |
An unknown hard- or software error has occurred. |
Disconnect the servo drive from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff branch office that is responsible for you. |
You have selected and parametrized an unsuitable resolver. |
Please check the resolver parameter in the IDN "P-0-0150". |
Further Information |
---|
AX5000_IDN-Description: "P-0-0150 -->Process channel-->Data-->Resolver" |