FA82, Feedback "Resolver": Initialization of the sampling instance failed

Initialization of the sampling time points has failed.

Diagnostic Code (Hex.)

Diagnostic Code (Dez.)

FA82

64130

Class

Type

Error

Runtime error

Standard Reaction

Reset

Open loop ramp

Execute Reset-Command (S-0-0099).

Possible Causes

Solutions

The resolver cabling is faulty.

Please check the cabling.

An unknown hard- or software error has occurred.

Disconnect the servo drive from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff branch office that is responsible for you.

You have selected and parametrized an unsuitable resolver.

Please check the resolver parameter in the IDN "P-0-0150".

Further Information

AX5000_IDN-Description: "P-0-0150 -->Process channel-->Data-->Resolver"