FA48, Feedback process channel error (1Vss)
Feedback process channel error (1Vss): quadrature encoder error
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
---|---|
FA48 |
64072 |
Class |
Type |
---|---|
Error |
Runtime error |
Standard Reaction |
Reset |
---|---|
Open loop ramp |
Execute Reset-Command (S-0-0099). |
Possible Causes |
Solutions |
---|---|
The pulse sequence of the digital traces (cosine and sine) is incorrect. |
Check the cable screening and screen connection of all cables to the devices. Check whether all components are earthed on the same potential. Check whether the AX5000 was securely attached to the metallic rear panel and whether the panel is earthed. |
The spacing between the edges is too small. |