F872, Feedback "AX572x": Position is invalid
The AX5000 has detected a position error.
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
---|---|
F872 |
63602 |
Class |
Type |
---|---|
Error |
Runtime error |
Standard Reaction |
Reset |
---|---|
Open loop ramp |
Execute Reset-Command (S-0-0099). If the drive is still in OP it will switch to SafeOp while executing the reset. |
Possible Causes |
Solutions |
---|---|
The feedback system is defective. |
Check the feedback system. |
An unknown hard- or software error has occurred. |