F78B, Feedback "general": Initialization failed
The initialization of the feedback parameter channel has failed. The digital name plate could not be read (EnDat).
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
---|---|
F78B |
63371 |
Class |
Type |
---|---|
Error |
Runtime error |
Standard Reaction |
Reset |
---|---|
The power stage is already switched off |
Execute Reset-Command (S-0-0099). |
Possible Causes |
Solutions |
---|---|
On the basis of the parametrization of the IDN P-0-0150 or P-0-0180, check whether you have parametrized the IDN to match the feedback system. |
Change the parametrization if necessary. |
An unknown hard- or software error has occurred. |
Disconnect the servo drive from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff branch office that is responsible for you. |
The feedback system is defective. |
Check the feedback system. |
![]() | Please consider this note! A digital name plate exists only in Beckhoff motors from the AM3000 series. |
Further Information |
---|
AX5000_IDN-Description: "P-0-0150" and "P-0-0180" |