F78A, Feedback "general": Initialization failed
The initialization of the feedback parameter channel has failed (EnDat).
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
---|---|
F78A |
63370 |
Class |
Type |
---|---|
Error |
Runtime error |
Standard Reaction |
Reset |
---|---|
The power stage is already switched off |
Execute Reset-Command (S-0-0099). |
Possible Causes |
Solutions |
---|---|
The feedback line is defective. |
Check the line. |
Wrong feedback system. |
Enter the correct feedback system. |
The feedback system is defective. |
Check the feedback system. |
An unknown hard- or software error has occurred. |
Disconnect the servo drive from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff branch office that is responsible for you. |