F742, Feedback "general": Invalid commutation offset
The commutation offset entered in the digital name plate of the motor is invalid.
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
---|---|
F742 |
63298 |
Class |
Type |
---|---|
Error |
Runtime error |
Standard Reaction |
Reset |
---|---|
The power stage is already switched off |
Execute Reset-Command (S-0-0099). |
Possible Causes |
Solutions |
---|---|
The commutation offset has not been entered in the digital name plate or the value is not plausible. |
Exchange the motor. |
An unknown hard- or software error has occurred. |
Disconnect the servo drive from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff branch office that is responsible for you. |
![]() | Please consider this note! It is not sufficient just to exchange the feedback system, because the commutation offset must be determined and entered in the factory. |