F73F, Feedback "general": Feedback id has been incorrectly parametrized

The internal ID parametrized in the feedback system does not correspond to the ID entered in the IDN "P-0-0150" or "P-0-0180".

Diagnostic Code (Hex.)

Diagnostic Code (Dez.)

F73F

63295

Class

Type

Error

Parameter error

Standard Reaction

Reset

The power stage is already switched off

Execute Reset-Command (S-0-0099).

Possible Causes

Solutions

You have selected an incorrect feedback system.

Compare the selected feedback system with the actually existing one.

The feedback database was incorrectly parametrized.

Call our support dept. and replace the feedback database.

During the motor replacement a motor with different feedback was connected.

Please correct the feedback-parameterization.

Further Information

AX5000_IDN-Description: "P-0-0150-->Parameter channel-->Identifier" or "P-0-0180-->Parameter channel-->Identifier"