F145, Initialization of the feedback failed
The initialization of the feedback failed.
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
---|---|
F145 |
61765 |
Class |
Type |
---|---|
Error |
Runtime error |
Standard Reaction |
Reset |
---|---|
Open loop ramp |
Execute Reset-Command (S-0-0099). |
Possible Causes |
Solutions |
---|---|
The feedback system has been incorrectly parametrized. |
Check the parametrization of the feedback system (P-0-0150 or P-0-0180). |
There is an internal hardware or software error. |
Disconnect the servo drive from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff branch office that is responsible for you. |
Further Information |
---|
AX5000_IDN-Description: "P-0-0150" or "P-0-0180" |