F0B7, Serial flash error
No write access to the serial flash memory.
|
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
|---|---|
|
F0B7 |
61623 |
|
Class |
Type |
|---|---|
|
Error |
Runtime error |
|
Standard Reaction |
Reset |
|---|---|
|
Closed loop ramp |
A reset is not possible. A fatal hard- or software error occured and the transition PreOp->SafeOp is blocked. |
|
Possible Causes |
Solutions |
|---|---|
|
No write access to the serial flash memory during firmware download. |
Disconnect the servo drive from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff branch office that is responsible for you. |
|
The system data could not be written to the serial flash memory during operation. |
Disconnect the servo drive from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff branch office that is responsible for you. |