F0B0, Serial Flash error
No write access to the serial flash memory.
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
---|---|
F0B0 |
61616 |
Class |
Type |
---|---|
Error |
Runtime error |
Standard Reaction |
Reset |
---|---|
Closed loop ramp |
A reset is not possible. A fatal hard- or software error occured and the transition PreOp->SafeOp is blocked. |
Possible Causes |
Solutions |
---|---|
No write access to the serial flash memory during firmware download. |
Disconnect the servo drive from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff branch office that is responsible for you. |
The system data could not be written to the serial flash memory during operation. |
Disconnect the servo drive from the mains (including the 24 V power supply) and start a new attempt. If this error occurs repeatedly, please call the Beckhoff branch office that is responsible for you. |