Technical data
Nominal motor current | Motor cable length | Servo drive | Motor choke | ||
|---|---|---|---|---|---|
max. 400 V | ≥25 m to 100 m | AX5101, AX5103, AX5106, AX5112, | AX2090-MD50-0012 | ||
max. 480 V | >20 m to 100 m | ||||
max. 400 V | ≥25 m to 50 m | AX5118 and AX5125 | AX2090-MD50-0025 | ||
max. 480 V | >20 m to 50 m | ||||
Data | AX2090-MD50-0012 | AX2090-MD50-0025 | |||
Nominal voltage | 480 V AC | 480 V AC | |||
Rated frequency | 0 – 60 Hz | 0 – 60 Hz | |||
Test voltage cable/cable for 2 s | 1770 V DC | 1770 V DC | |||
Test voltage cables/housing for 2 s | 2700 V DC | 2700 V DC | |||
Rated temperature | 50 °C | 50 °C | |||
Inductance | 0.2 mH | 0.12 mH | |||
Continuous load operation (S1) | 12 A | 25 A | |||
Climate category (IEC 60068-1) | 25/100/21 | 25/100/21 | |||
Approval | UL 1283 / UL File No. E10122 | UL 1283 / UL File No. E10122 | |||
Resistance [type] | 25 mΩ | 15 mΩ | |||
Power loss | 5 - 25 W1)3) | 10 -35 W2)4) | |||
Weight | 2.9 kg | 8.5 kg | |||
1)nominal current 1 - 12 A
2)nominal current 18 - 25 A
3)measured at max. cable length of 100 m
4)measured at max. cable length of 50 m