Disassembly

WARNING

Serious injuries due to premature disconnection from the
supply network

There is still a life-threatening voltage of > 848 V DC on the capacitors after disconnection from the supply network. Serious or even fatal injuries may result if this is ignored.

  • Keep to the waiting times after disconnection from the supply network

AX8000 series

Discharge time [min]

AX8108, AX8118, AX8128

30

AX8206

30

AX8525, AX8540

30

AX8600

30

AX8620, AX8640

30

AX8820

30

AX8831, AX8832

30

AX5000 series

Discharge time [min]

AX5101 to AX5125

5

AX5201, AX5203, AX5206

5

AX5140, AX5160, AX5172

15

AX5190, AX5191

30

AX5192, AX5193

45

AMP8000 series

Discharge time [min]

AMP8620-2005-0xxx

30

AMP8805-10x0-0000

30

Disassembly 1:

Do not remove components from the products

Only Beckhoff Automation GmbH & Co. KG is permitted to remove components.

Contact Beckhoff Service for further information.

Removing the braking resistor from the machine

Remove cables and electrical connections
Loosen and remove the braking resistor fixing screws
Transport the braking resistor to the workplace or put it into storage