Conditions
Care must be taken that the braking resistor and individual components are not damaged during transport and storage. Observe the specifications in the following chapters and comply with the following conditions:
- Avoid electrostatic charging
- Avoid contact with highly insulating materials
- Temperature: -15 °C to +70 °C, maximum fluctuation 20 K per hour
- Air humidity: relative humidity max. 85 %, non-condensing
- Use of suitable means of transport
- Use the vendor's original packaging
The table shows the maximum stacking height in which you may store and transport the braking resistors in their original packaging on a pallet:
Braking resistor type | Stacking height [pieces] |
|---|---|
AX2090-BW65-04xx | 8 |
AX2090-BW65-05xx | 8 |
AX2090-BW65-15xx | 5 |
AX2090-BW65-16xx | 5 |