Data for operation and environment
![]() | Operate mains choke only under the specified environmental conditions Operate the mains choke only in accordance with the operating and environmental specifications listed in this chapter. This ensures a long service life and proper operation. Temperatures above +40 °C and encapsulated installation can shorten the life of the mains choke. |
Beckhoff products are designed for operation under certain environmental conditions, which vary according to the product. The following specifications must be observed for operation and environment in order to achieve the optimum service life of the products.
Environmental requirements | |
|---|---|
Ambient temperature during operation | -10 °C...+40 °C Extended temperature range up to 55 °C with power derating of 2 % / K |
Ambient temperature during storage | -25 °C...+70 °C |
Permissible humidity in operation | 15 % … 95 %; condensation not permitted |
Pollution degree | P2 according to DIN EN IEC 61558-1 |
Specifications for intended use | |
Insulation material class | IEC = F according to DIN EN 60085 UL = 155 |
Protection rating | IP00 according to DIN EN 60529 |
Installation position | Vertical or horizontal |
Approvals | cURus See chapter Directives and standards |