AX2090-L807 | Fan cover - Version 1.0

Mounting

 
 SmallWarningYellow WARNING
Mount the fan cover only when the motor is completely stopped
Only mount the fan cover when the motor has come to a complete stop.
Rotating motors can cause serious injury whren the fan cover is mounted.
Note
Clean the working environment
Workplaces and their immediate surroundings must be tidy and dust-free. Avoid dirt in tapped holes.
Non-observance can result in damage and malfunction of the components.
1.
Attach the motor to the machine
2.
For AM807x series: release and remove the eyebolts on the motor housing
3.
Push the fan cover [1] onto the housing up to the mechanical stop
4.
Make sure that on both sides of the motor the elongated holes [3] are aligned with the screw connection devices [2]
5.
Fit screws [4] to [7]
6.
Fit nuts [8] and [11] with washers [9] and [10]
7.
Observe tightening torques:
 
Screws
Nuts
3 Nm size 2.5
2.5 Nm, size 7

Use Beckhoff control cable

Use the pre-assembled control cable ZK4054-6400-0xxx to connect the fan cover

8.
Plug the power connector [12] into the power box [13] of the motor
9.
Hand-tighten power connector [12] and check for tight fit