Shaft offset
The purpose of the elastomer couplings is to compensate the lateral, axial and angular shaft offsets.
Number | Meaning |
|---|---|
1 | Lateral offset |
2 | Axial offset |
3 | Angular offset |
![]() | Prolonged service life through precise alignment The service life of the elastomer coupling will be prolonged by precise alignment. The load on the bearing is thereby reduced so that the running smoothness of the entire drivetrain is positively affected. |
The maximum permissible guide values for the different types of offset are given in the Technical data. Operationally-related influences such as thermal elongation can be compensated by adhering to the permissible guide values. The maximum permissible guide values must be reduced if several types of offset occur simultaneously. The sum of the actual offsets as a percentage of the maximum value may not exceed 100%.