Temperature switch

Note
Destruction of the brake resistor!

The temperature switch is exclusively used for temperature monitoring. The brake resistor is not switched off.

 

The temperature switch has a potential-free N/C contact, which enables immediate response to any overload of the brake resistor through analysis in the AX5000 or the PLC. Connect the cable directly to a free input of plug "X06". Then parameterize it such that the AX5000 stops the motor(s) with an emergency ramp or the PLC reads and processes this input.

Type

Switching temperature

Switching current
24 VDC or 230 VAC

[°C]

[A]

AX2090-BW50-0300

180

2

AX2090-BW50-0600

180

2

AX2090-BW50-1600

180

2

AX2090-BW51-1000

180

2

AX2090-BW51-3000

85

2

AX2090-BW51-6000

85

2

AX2090-BW52-3000

85

2

AX2090-BW52-6000

85

2

AX2090-BW53-3000

85

2

AX2090-BW53-6000

85

2

AX2090-BW54-3000

85

2

AX2090-BW54-6000

85

2