STATIO

ASCII - Command

STATIO

 

 

Syntax Transmit

STATIO

 

Syntax Receive

STATIO <Data>

Available in

 

Type

Variable ro

MMI

Yes

ASCII Format

7 x Integer8

CANBus Object Number

35FC (hex)

DIM

-

PROFIBUS PNU

1852 (dec) IND = 0000xxxx (bin)

Range

0,1 (=State)

DPR

252 (dec)

Default

-

 

Opmode

All

Data Type Bus/DPR

-

Drive State

-

Weightning

 

Start Firmware

1.20

 

Configuration

No

Revision

1.3

Function Group

Digital I/O

EEPROM

No

Short Description

I/O Status

Description

The STATIO command returns the actual state of the digital inputs and outputs of the servo amplifier, in the following sequence.

IN1 IN2 IN3 IN4 ENABLE OUT1 OUT2

A 0 at the appropriate position means that the corresponding input/output is in the Low state, a 1 signifies the High state.