PIOBUF

ASCII - Command

PIOBUF

 

 

Syntax Transmit

PIOBUF

 

Syntax Receive

PIOBUF <Data>

Available in

 

Type

Variable rw

MMI

Yes

ASCII Format

String

CANBus Object Number

35CC (hex)

DIM

-

PROFIBUS PNU

1804 (dec) IND = 0000xxxx (bin)

Range

-

DPR

204 (dec)

Default

-

 

Opmode

-

Data Type Bus/DPR

-

Drive State

-

Weightning

 

Start Firmware

1.73

 

Configuration

No

Revision

1.3

Function Group

Communication

EEPROM

No

Short Description

Profibus data

Description

This command reads out the present PROFIBUS input and output buffers. The output buffer handles the data flow from the control system to the Drive, and the input buffer handles the data flow from the Drive to the control system. Each buffer is 20 bytes long (telegram length) and is put together from the PKW section (8 bytes. i.e., 4 words) and the PZD section (12 bytes, 6 words). The individual bytes are in hexadecimal format.

PIOBUF provides 20 bytes of output buffer in the first line, and 20 bytes of input buffer in the second line.

If the communication over the PROFIBUS is interrupted or faulty, then a fault message “ERR [PIOBUF] NO DATA EXCHANGE SPC3 - INTERRUPT” is generated.