INPT

ASCII - Command

INPT

 

 

Syntax Transmit

INPT [Data]

 

Syntax Receive

INPT <Data>

Available in

 

Type

Variable rw

MMI

Yes

ASCII Format

Integer16

CANBus Object Number

3630 (hex)

DIM

Milliseconds

PROFIBUS PNU

1904 (dec) IND = 0000xxxx (bin)

Range

1 .. 32000

DPR

304 (dec)

Default

10

 

Opmode

8

Data Type Bus/DPR

Integer16

Drive State

-

Weightning

 

Start Firmware

2.08

 

Configuration

No

Revision

1.3

Function Group

Position Controller

EEPROM

Yes

Short Description

In-Position Delay

Description

The INPT command defines a delay time for the In-Position signal. At the start of a motion block, the In-Position signal is removed, and the monitoring of the In-Position window is only activated again after the end of this preset time. This function is especially important for positioning tasks within the In-Position window. In such a case, it ensures that the In-Position signal is always removed for a definite time.See also INPOS