ADDRFB
ASCII - Command | ADDRFB |
|
| |
Syntax Transmit | ADDRFB [Data] |
| ||
Syntax Receive | ADDRFB <Data> | Available in |
| |
Type | Variable rw | MMI | No | |
ASCII Format | Integer16 | CANBus Object Number | 369C (hex) | |
DIM | - | PROFIBUS PNU | 2012 (dec) IND = 0000xxxx (bin) | |
Range | 0 .. 63 | DPR | 412 (dec) | |
Default | 0 |
| ||
Opmode | All | Data Type Bus/DPR | Integer16 | |
Drive State | - | Weightning |
| |
Start Firmware | 4.91 |
| ||
Configuration | No | Revision | 1.6 | |
Function Group | Communication | EEPROM | Yes | |
Short Description | Fieldbus address at AX2500 Slave | |||
Description
ADDRFB defines the fieldbus address of the AX2500 for CAN / PROFIBUS and SERCOS. After changing the parameter, a parameter save (SAVE) has to be initiated and the drive has to be reset.
This address is used only for the external Fieldbus communication. The internal AX2500 communication still uses the address given by ADDR.
If ADDRFB = 0, the internal address ADDR is used.