ADDRFB

ASCII - Command

ADDRFB

 

 

Syntax Transmit

ADDRFB [Data]

 

Syntax Receive

ADDRFB <Data>

Available in

 

Type

Variable rw

MMI

No

ASCII Format

Integer16

CANBus Object Number

369C (hex)

DIM

-

PROFIBUS PNU

2012 (dec) IND = 0000xxxx (bin)

Range

0 .. 63

DPR

412 (dec)

Default

0

 

Opmode

All

Data Type Bus/DPR

Integer16

Drive State

-

Weightning

 

Start Firmware

4.91

 

Configuration

No

Revision

1.6

Function Group

Communication

EEPROM

Yes

Short Description

Fieldbus address at AX2500 Slave

Description

ADDRFB defines the fieldbus address of the AX2500 for CAN / PROFIBUS and SERCOS. After changing the parameter, a parameter save (SAVE) has to be initiated and the drive has to be reset.

This address is used only for the external Fieldbus communication. The internal AX2500 communication still uses the address given by ADDR.

If ADDRFB = 0, the internal address ADDR is used.