Data for operation and environment

Beckhoff products are designed for operation under certain environmental conditions, which vary according to the product. The following specifications must be observed for operation and environment in order to achieve the optimum service life of the products.

Notice

Operate stepper motor drive ASI8100 only under the specified environmental conditions

Operate the ASI8100 only under the operating and environmental conditions specified in this chapter. This ensures a long service life and proper operation.

Temperatures above 40°C and encapsulated installation can shorten the service life of the ASI8100.

Environmental requirements

Climate category

3K3 according to EN 60721

Ambient temperature during operation

-10 °C to +40 °C, with power derating to +50 °C

Ambient temperature during transport

Maximum fluctuation 20 K/hour:
-20 °C to +60 °C

Ambient temperature during storage

Maximum fluctuation 20 K/hour:
-20 °C to +60 °C

Permissible humidity in operation

20 % to 90 % relative humidity, no condensation

Permissible humidity during transport and storage

90 % relative humidity, no condensation

 

Specifications for intended use

Cooling

Convection: adequate self-surface cooling is to be ensured.

Insulation material class

B; 130°C according to IEC 60085

Vibration resistance

2 g, 58.1...500 Hz in accordance with IEC 60068-2-6

Shock resistance

5 g, 30 ms in accordance with IEC 60068-2-27

Approvals

CE, EAC, UL (in preparation)