Mounting motor to gear unit
| |
Burns due to contact with hot output elements Hot components can cause severe burns to body parts and limbs.
|
Notice | |
Damage due to offset mounting An offset will cause unacceptable vibration and the destruction of the ball bearings and the coupling.
|
Insert reducing sleeve into gear unit
- ►Insert the reducing sleeve [1] centered and straight into the gear unit [2]
- ►The opening of the reducing sleeve [3] should be in line with the opening of the clamping hub [4]
Bring ASI8100 and gear unit together
- ►Align the drive shaft of the stepper motor [1] and the bearing of the gear unit [2] in the center and push them together
- ►Ensure that the flattened side of the drive shaft [3] is under the opening of the reducing sleeve [4]
Screw stepper motor and gear unit together
- ►Fit a washer [2] to each of the four fastening screws [1]
- ►Insert the fastening screws [1] in the through holes in the gear flange and screw them into the threaded holes in the stepper motor
- ►Tighten the fastening screws [1] to a torque of 0.6 Nm
Screw on clamping hub
- ►Rotate assembly by 90 degrees
- ►Insert the hex key through the opening [1] of the gear unit [2] and screw the clamping hub inside